Case Series on the Clinical Performance of VA Clavicle and Clavicle Hook Plate 2.7 Systems
Start Date
7/10/2024
Completion Date
9/30/2029
Summary
The purpose of this study is to gather early and mid- to long-term evidence to confirm the clinical performance, safety and use of the Clavicle Plate and Clavicle Hook Plate System. A minimum of 76 patients with clavicle fractures or dislocations of the AC joint surgically treated with any plate from the DPS VA-LCP Clavicle System will be enrolled in this observational post-market clinical investigation. Outcomes will be collected until up to 2 years after surgery.
Detailed Description
Common problems with existing clavicular plates are poor plate 'fit,' unbalance fixation, plate prominence, associated soft tissue irritation, subacromial pain, plate and/or fixation failure (due to unbalanced fixation) and high reoperation rate (for plate removal) \[1-3\]. The newly developed DePuy Synthes (DPS) variable angle locking compression plate (VA-LCP®) Clavicle 2.7 System was designed to address these problems. The system consists of lateral, shaft and medial plates and hook plates of different sizes to cover a wide variation in clavicular morphology and diverse fracture, fracture-dislocation and dislocation indications. The objective is to describe the short and long-term clinical performance and safety of both systems, as well as the functional outcomes of this patient population. Outcomes will be collected at baseline, 2 weeks, 6 weeks, 3 months, 6 months 1, and 2 years after surgery. In addition, the surgeons' experience and utility of the devices will be surveyed. For the short term evaluation, an interim analysis will be done as soon as 30 patients in each group have completed 6 months of follow-up (FU). The final evaluation of long-term outcomes will be done after 2 years of FU. All treatments and follow-up visits are according to standard of care.
Eligibility Criteria
Age Range: 18 years to No maximum
Interventions
DPS VA-LCP® Clavicle Plate 2.7 System; DPS VA-LCP® Clavicle Hook Plate 2.7 System
Conditions
Locations
Corewell Health
Grand Rapids, Michigan 49503
United States
Atrium Health Wake Forest Baptist
Winston-Salem, North Carolina 27157
United States
Prisma Health Richland Hospital
Columbia, South Carolina 29203
United States
Klinik Ottakring
Vienna, 1160
Austria
Universitätsklinikum Freiburg
Freiburg im Breisgau, 79106
Germany
Universitätsklinikum Münster
Münster, 48149
Germany
Luzerner Kantonsspital
Lucerne, 6000
Switzerland