Back to Trials
NCT05397951NARecruitingAccepts Healthy Volunteers

The Validation Study of Bioelectronics

University of North Carolina, Chapel Hill

Start Date

1/9/2024

Completion Date

11/1/2026

Summary

The purpose of this study is to investigate the safe wearability and basic functions of the multi-modality sensors fabricated in the PI lab.

Detailed Description

Members of this research team have developed innovative, wearable devices capable of being comfortably and continuously worn while recording diverse physiologic measurements. The purpose of this study is to validate the safe wearability and basic functions of the novel biocompatible electronic sensor that will allow continuous, non-invasive physiological measurements. This study aims to obtain preliminary data on the safety and functional aspects of the developed devices and compare it to approved medical equipments (including Abbott Medquip Oximeter, Omron blood pressure monitor, and Vicorder device for pulse wave velocity), which will pave the way for future study that focuses certain disease model. Participants will be randomly assigned to Condition A, and wear the devices before and after exercise for 15 minutes each time, or Condition B and wear the devices for 2 hours continuously. During their 1-hour or 2.5-hour lab visit, study participants will wear the biocompatible electronic sensors and three approved medical devices during a slow deep breath, before and after a 6-minute brisk walk, or for an extended period of time (2 hours). Participants will return to the lab for two brief visits, 48 and 96 hours after the device wearing, to determine if any suspected adverse events related to study procedures or devices emerged after they left the research site. For the future study, we will plan to 1) optimize the devices for use in patients needing FiO2 weaning, 2) demonstrate the reliability, and accuracy of these devices for continuous physiological measurements, including but not limited to blood pressure, heart rate (HR), cerebral blood flow, temperature, glucose concentration, and respiratory rate, and 3) demonstrate these devices are preferred by patients to current measurement tools. Once validated, such sensors could fundamentally change the way blood flow, blood pressure, or related parameters are monitored for patients, eliminating risks associated with invasive monitoring, allowing continuous, real-time detection of clinically meaningful changes in the patients, advancing knowledge of hormonal signatures and physiological signals preceding clinically meaningful events.

Eligibility Criteria

Age Range: 18 years to 99 years

Inclusion Criteria: * Individuals with ages between 18 and 99. * Healthy individuals (not known to suffer any significant illness relevant to the proposed study). Exclusion Criteria: * Pregnant or lactating. * History of active (clinically significant) skin disorders that make skin vulnerable to contact conventional electronic devices. * History of allergic response to silicones or adhesives (such as 3M Tegaderm). * Broken, damaged or irritated skin or rashes near the sensor application sites (finger, wrist, temple, subclavian, arm, neck, and thigh). * Subjects who are physically or cognitively unable to normally perform activities of daily living, assessed at the discretion of the investigator to ensure safe completion of study tasks. * Subjects who are unable to participate in moderate exercise for 6 minutes.

Interventions

DEVICE

Multi-modality Noninvasive Biosensor

DEVICE

Oximeter

DEVICE

Portable Blood Pressure Monitor

DEVICE

Vicorder Pulse Wave Velocity Monitor

Interested in This Trial?

Contact the trial locations directly using the information below to learn more about enrollment.

Expressing interest lets you review the study and consent before we connect you with the research site.

Conditions

HealthyHealth Behavior

Locations

Kenan Laboratories at the University of North Carolina at Chapel Hill

Chapel Hill, North Carolina 27514

United States