Femoral BMD Change Following Cemented or Cementless Total Knee Arthroplasty
Start Date
3/6/2025
Completion Date
6/1/2028
Summary
The purpose of this study is to examine femur bone mineral density (BMD) change before and after surgery in patients receiving cemented or cementless total knee arthroplasty (TKA). performed with manual or robotic methods. 100 participants will be enrolled and can expect to be on study for up to 26 months.
Detailed Description
It has previously been reported that total knee arthroplasty (TKA) causes major femur bone loss (\~18% within 1 year). Prior studies did not examine different surgical methods, such as the use of cement or robotics, in TKA. The investigators hypothesize that previously reported differences in distal femur BMD change following TKA exist between patients receiving cemented vs. cementless prostheses. Specific Aim 1: In the entire study cohort, our primary endpoint is to estimate percent BMD change 12 and 24 months after TKA at the distal femur 25% region of interest (ROI). Specific Aim 1a: To compare percent BMD change 12 and 24 months after TKA at the distal femur 25% ROI in cemented vs uncemented implants. Specific Aim 1b: To compare percent BMD change 12 and 24 months after TKA at the distal femur 25% ROI in those receiving robotic vs manual implants. Specific Aim 2: In the entire study cohort, our secondary endpoints are to estimate percent BMD change 12 and 24 months after TKA at a.) the distal femur 15% ROI and b.) a proximal tibial ROI Specific Aim 2a: To compare percent BMD change 12 and 24 months after TKA at the distal femur 15% ROI and proximal tibial ROI in cemented vs uncemented implants. Specific Aim 2b: To compare percent BMD change 12 and 24 months after TKA at the distal femur 15% ROI and proximal tibial ROI in in those receiving robotic vs manual implants. Exploratory Aim 1: Compare patient reported pain and function at 2 weeks, 3 months, 12 months, and 24 months; 1. in those receiving cemented and cementless implants. 2. in those receiving robotic vs manual implants. Exploratory Aim 2: Evaluate leg lean mass change as measured by DXA and BIS at 2 weeks, 3 months, 12 months, and 24 months over time. 1. In the entire cohort 2. in those receiving cemented and cementless implants. 3. in those receiving robotic vs manual implants.
Eligibility Criteria
Age Range: 55 years to No maximum
Interventions
Cement
Cementless
Manual Surgery
Robotic Surgery
Conditions
Locations
UW School of Medicine and Public Health
Madison, Wisconsin 53792
United States