Skip to main content
Back to Trials
NCT07710352NARecruiting

Low Gas Pressure vs Standard Gas Pressure in Robotic Surgery

Weill Medical College of Cornell University

Start Date

7/30/2026

Completion Date

2/1/2027

Summary

During surgery that is done using a robot, the surgeon needs to put carbon dioxide gas into the belly to lift the belly wall. This is done so the surgeon can adequately see all the body organs and operate safely. Many surgeons currently use a standard pressure of 15 mmHg (a unit to measure pressure). However, many patients find the use of this pressure to be painful after surgery. New research has shown that using a lower pressure with a device called "AirSeal" can safely reduce pain and lead to faster recovery after surgery. The goal of this clinical trial is to learn if using a lower gas pressure with the AirSeal device during robotic surgery, compared to standard gas pressure with conventional devices, helps adults feel less pain and recover faster. The study includes adults aged 18 or older having robotic at New York-Presbyterian Hospital/Weill Cornell Medical Center. The main questions this clinical trial aims to answer are: 1. Does using lower gas pressure shorten the time people spend in the recovery room after surgery? 2. Does using lower gas pressure lead to less pain and reduce the need for pain medicine after surgery?

Detailed Description

Robotic surgeries require the use of pneumoperitoneum, which is a standard of care as it creates a working environment to utilize minimally invasive tools to accomplish surgical procedures. However, there is no uniform standard pressure (usually between 12-15 mmHg). Moreover, maintaining the same pressure throughout the procedure can be inconsistent at best. Elevations in pneumoperitoneum cause significant stretch to the peritoneum which results in significant postoperative pain, longer post-anesthesia care unit (PACU) stay times, and higher opioid consumption. These effects are amplified to a higher degree in patients with severe obesity. If the pressures can be maintained and set to lower levels, then patients may have the opportunity to recover in the immediate postoperative period. The AirSeal Robotic Solution (CONMED Corporation) is an FDA 510(k)-cleared carbon dioxide insufflation device that is indicated for use in robotic-assisted surgery. This study is a prospective, single-center, single-blind, double-arm parallel-group randomized controlled trial that aims to determine if the use of low-pressure (8 mmHg) AirSeal insufflation, compared to standard-pressure (15 mmHg) pneumoperitoneum, provides superior patient outcomes in terms of post-operative recovery time and convalescence. During the preoperative evaluation, participants will be consented and enrolled into the trial. Participants will then be randomly allocated to either low-pressure AirSeal insufflation (8 mmHg) or standard-pressure pneumoperitoneum (15 mmHg). Patients and outcome assessors will be blinded to allocation; however, for safety purposes, the operating surgeon and anesthesiologist cannot be blinded. Intraoperative data (including operation time, estimated blood loss, abdominal pressure, and pressure deviations) will be recorded. Participant data related to comorbidities (i.e. body mass index, American Society of Anesthesiologists physical status, hypertension, diabetes, obstructive sleep apnea, chronic obstructive pulmonary disease/asthma, and smoking status) will be collected from the electronic medical record.

Eligibility Criteria

Age Range: 18 years to No maximum

Inclusion Criteria: * Aged 18 years or older * Scheduled to undergo robotic-assisted surgery at New York-Presbyterian/Weill Cornell Medical Center * American Society of Anesthesiologists physical status I-III * Able to understand and provide written informed consent in English Exclusion Criteria: * American Society of Anesthesiologists physical status IV or higher (i.e. a severe systemic disease that is a constant threat to life such as decompensated heart failure) * Chronic opioid use (≥30 morphine milligram equivalents per day for ≥30 days within the past 6 months) * Current pregnancy * Inability to understand and provide informed consent in English * Inability to provide informed consent due to cognitive impairment or other conditions impacting decision-making capacity * Scheduled open or laparoscopic surgeries

Interventions

DEVICE

AirSeal Robotic Solution

OTHER

Standard-pressure pneumoperitoneum (15 mmHg)

Interested in This Trial?

Contact the trial locations directly using the information below to learn more about enrollment.

Expressing interest lets you review the study and consent before we connect you with the research site.

Conditions

Robotic SurgeryPneumoperitoneum

Locations

New York-Presbyterian/Weill Cornell Medical Center GI Metabolic and Bariatric Surgery

New York, New York 10021

United States